Join member to enjoy discounts and Points Double gift
e20-535 Exam
Networked Storage - NS Implementation
- Exam Number/Code : e20-535
- Exam Name : Networked Storage - NS Implementation
- Questions and Answers : 120 Q&As
- Update Time: 2009-12-14
- Price:
$ 155.00$ 130.00
EMC Certification Testing study guide
EMC Certification EMC Certification Testing EMC Proven Professional Build credibility. Get Proven! The award-winning EMC Proven Professional training and certification framework helps students achieve information storage and management expertise — expanding opportunities to move from individual contributor to strategic technology advisor. EMC certification delivers the knowledge and skills to increase productivity, while maximizing your time with flexible training options. Receive on-the-…
e20-535 Exam Description
It is well known that latest e20-535 exam test is the hot exam of EMC certification. exam4test offer you all the Q&A of the e20-535 real test . It is the examination of the perfect combination and it will help you pass e20-535 exam at the first time!
Why choose Exam4test e20-535 braindumps
- After you purchase our product, we will offer free update in time for 90 days.
- Comprehensive questions and answers about e20-535 exam
- e20-535 exam questions accompanied by exhibits
- Verified Answers Researched by Industry Experts and almost 100% correct
- e20-535 exam questions updated on regular basis
- Same type as the certification exams, e20-535 exam preparation is in multiple-choice questions (MCQs).
- Tested by multiple times before publishing
- Try free e20-535exam demo before you decide to buy it in exam4test.com
Exam4test e20-535 braindumps
Quality and Value for the e20-535 Exam
100% Guarantee to Pass Your e20-535 Exam
Downloadable, Interactive e20-535 Testing engines
Verified Answers Researched by Industry Experts
Drag and Drop questions as experienced in the Actual Exams
Practice Test Questions accompanied by exhibits
Our Practice Test Questions are backed by our 100% MONEY BACK GUARANTEE.
Exam4test e20-535 Exam Features
Quality and Value for the e20-535 Exam
Exam4test e20-535 Practice Exams for EMC e20-535 are written to the highest standards of technical accuracy, using only certified subject matter experts and published authors for development.
100% Guarantee to Pass Your e20-535 Exam
If you prepare for the exam using our Exam4test testing engine, we guarantee your success in the first attempt. If you do not pass the EMC Certification e20-535 exam (Networked Storage - NS Implementation) on your first attempt we will give you a FULL REFUND of your purchasing fee AND send you another same value product for free.
EMC e20-535 Downloadable, Printable Exams (in PDF format)
Our Exam e20-535 Preparation Material provides you everything you will need to take your e20-535 Exam. The e20-535 Exam details are researched and produced by Professional Certification Experts who are constantly using industry experience to produce precise, and logical. You may get questions from different web sites or books, but logic is the key. Our Product will help you not only pass in the first try, but also save your valuable time.
e20-535 Downloadable, Interactive Testing engines
We are all well aware that a major problem in the IT industry is that there is a lack of quality study materials. Our Exam Preparation Material provides you everything you will need to take a certification examination. Like actual certification exams, our Practice Tests are in multiple-choice (MCQs)
Our EMC e20-535 Exam will provide you with exam questions with verified answers that reflect the actual exam. These questions and answers provide you with the experience of taking the actual test.
High quality and Value for the e20-535 Exam:100% Guarantee to Pass Your EMC Certification exam and get your EMC Certification Certification.
Exam : EMC E20-535
Title : EMC (r) Networked Storage - NS Implementation
1. An FSN device is configured with physical devices of dissimilar characteristics. What is the reason for implementing the "primary" option on this device?
A. To ensure that both paths are always active
B. To allow connectivity to dissimilar network switches
C. To ensure the best path is given priority for functionality
D. To prevent the primary path for automatically resuming on recovery
Answer: C
2. What is a characteristic of Kerberos?
A. Uses access tokens to hold a user's SID
B. Key Distribution Center manages the keys
C. Security encryption used by authentication protocols
D. Provides encryption of passwords sent to Domain controllers
Answer: B
3. When using a Symmetrix in a Fibre Channel environment, how is the Fibre Channel WWN of the FA determined?
A. Hardware manufacturer, system serial number, and FA slot ID
B. iSNS registration number, system serial number, and FA slot ID
C. Hardware manufacturer, system IP address, and FA serial number
D. iSNS registration number, system IP address, and FA serial number
Answer: A
4. You are performing a Data Mover failover test of server_2 at a time that will pose minimal impact to corporate users. The Data Mover is used only to export CIFS shares.
What should be done to verify the failover was successful?
A.Check that all file systems were mounted using server_mount
Check that all file systems were exported using server_export
Verify that the CIFS service has started using server_cifs
Verify network connections using ping to ping the default gateway
B.Check that all file systems were exported using server_export
Verify that the CIFS service has started using server_cifs
Verify network connections by accessing all data from network clients
Verify access to CIFS shares as a new user
C.Check that all file systems were mounted using server_mount
Check that all file systems were exported using server_export
Verify that the CIFS service has started using server_cifs
Verify network connections using server_sysconfig and server_ifconfig
D.Check that all file systems were mounted using server_mount
Check that all file systems were exported using server_export
Verify that the CIFS service has started using server_cifs
Verify network connections using server_ping to ping the default gateway
Answer: B
5. What is a component of CIFS?
A. NIS
B. FTP
C. NFS
D. UNC
Answer: D
6. As shown below, you have configured network interfaces in the following order:
The default gateway is 10.127.76.1.
When issuing server_ping to the default gateway, which network device will transmit the ping?
A. cge0
B. cge1
C. cge2
D. cge3
Answer: D
7. What accurately describes the process of adding a Data Mover to an NS-series Celerra?
A. The NS system must be powered off
B. The Control Station must be powered off
C. The Data Mover is added non-disruptively
D. The existing Data Mover must be powered off
Answer: C
8. You are performing a Data Mover failover test of server_2 at a time that will pose minimal impact to corporate users. After performing the failover, you verify that the standby Data Mover successfully mounts, exports all file systems, and takes over as server_2.
Five minutes after the failover, users begin reporting that they can no longer access some of their shares. After further investigation you find that, while most shares are accessible via the CIFS servers on server_2, all shares exported through the "finance1" CIFS server are inaccessible. You also learn that the "finance2" and "engineering1" CIFS servers on server_2 are working without problems.
What is the likely cause of the problem?
A. The CIFS service was not started on the standby Data Mover.
B. The CIFS service was not started for the "finance1" CIFS server.
C. New disks were added to the storage array but were never added to the configuration database for the standby Data Mover.
D. The network cable of the standby Data Mover, associated with the "finance1" CIFS server, is assigned to the incorrect VLAN.
Answer: D
http://www.exam4test.com/ The safer.easier way to get EMC Certification Certification.